Solid State Relay, AC control AC, SSR-10/25/40/60/80/100 Improved SSR

SSR-10AA/SSR-25AA/SSR-40AA/SSR-60AA/SSR-80AA/SSR-100AA, input control 80-240V AC, output load 24-380V AC, improve design voltage control

    description2

    Ordering information Table
    • Solid State Relay, DC control AC, SSR-1025406080100 DA detail (1)8s8
    • Solid State Relay, DC control AC, SSR-1025406080100 DA detail (2)po7
    Patent design, using the cover-protection model, easy to operate.
    Special electroplating for plate, anti-oxidation, well heat dissipation.
    Solid State Relay, DC control AC, SSR-1025406080100 DA detail (3)6av

    Features

    Current.0.5A~400A
    Voltage:12V~680V
    Small General outline
    Vacuum Weld Techinics
    Led indicator showing *ON* or *OFF*
    Protect Panel
    lEC standard
    Input & output type could chose 
    DC/AC AC/AC DC/DC

    Applications 

    • AC DC switch & Temp control
      Automate Control
      CNC machinery
      Packaging machinery 
      Textile machinery
      Glass machinery
      Plastic machinery
    • detail (3)j1y
    Solid state relay (SSR) is an advanced industrial control device that uses power semiconductor components as the main control component.  Compared with traditional magnetic contact industrial controllers, SSR has higher power, intelligence, digitalization, systematization and environmental protection development.
    SSR has two switching modes: zero-crossing type and random type.  The random type turns on immediately when receiving the input control signal, while the zero-crossing type requires the load voltage to reach the zero area before turning on.  Both types can shut down when the current drops below maintenance levels.  The zero-crossing type may cause maximum half-cycle delay, but reduces load effects and RF interference, making it an ideal switching device.  Random types provide fast response and are suitable for dimmers, thermostats, resistive loads and some inductive load applications.
    When turning off the SSR, the triac may experience a large rate of rise (dv/dt) if the phase currents and voltages are different.  If dv/dt exceeds the triac's standard (300V/us), it may cause delayed shutdown or failure.  Using powerful SSR with anti-parallel thyristors can greatly increase dv/dt (up to 500V/us).  Therefore, for capacitive or inductive loads, it is recommended to use powerful SSR. For example, Zenli's SSR are all powerful types.
    A solid-state voltage regulator includes a thyristor switching circuit, a resistor-capacitor phase shift circuit, a hysteresis circuit and an overvoltage absorption circuit.  Only an external potentiometer is needed to achieve AC power regulation and replace high contact voltage lighting supplies in many applications, allowing analog regulation of voltage, temperature, brightness, speed, and more.

    Specification

    input parameter

    output perameter

    Prolecion

    Safe Load

    Control Vollage

    Control

    Current

    Start Current

    Close Voltage

    Ooerating Current

    Ooerating Voltage

    Insulate Voltage

    Over Vollage

    Over  Current

    Resistive Load

    inductiveLoad

    Single Phase SSR

    DC/AC

    3-32VDC

    <20mA

    ≥25mA

    ≤15VDC

    10-120A

    90-480VAC

    ≥2500
    VAC

    RC Mov

    Fast Fuse

    60%

    40%

    AC/AC

    90-280VAC

    <30mA

    ≥25mA

    ≤10VAC

    10-120A

    24-240VAC

    Industry dass

    3-32VDC

    <20mA

    ≥25mA

    ≤15VDC

    100-800A

    90-480VAC

    DC/DC

    5-32VDC

    <25mA

    ≥25mA

    ≤15VDC

    10-40A

    12-250VDC

    Diode

    3Phase SSR

    3-32VDC

    <30mA

    ≥9ma

    ≤25VDC

    10-120A

    380V AC

    RCMOV

    FastFuse

    solid state voltage regulator

    Potentiometer 470KΩ/2W

    10-40A

    10-250VAC

    RCMOV

    FastFuse

    RC: Built-in resistance capacity absorption circuit
    MOV: External shunt metal oxide varistor.
    Notes 
    1.Strictly prohibit for load short circuit,Can use fast fuse.
    2.Ling time working current can't over 70% of the nominal value.
    3.Heatsink temperature can'tover75℃.
    4.Use at inductive load area, add varistor for protect is better.
    Recommended value of load type (Room temperature)

    Load type

    Pure Resistance

    Electric hot wire

    Incandescent lamp

    Transformer/Electromagnet

    1 phase AC motor

    3 phase AC motor

    value of load

    100%

    50-70%

    35-50%

    25-40%

    12-24%

    18-33%

    Electrical Characteristics

    Solid State Relay, DC control AC, SSR-1025406080100 DA detail 08v6d
    • Solid State Relay, DC control AC, SSR-1025406080100 DA detail (5)b2y

      Dissipative Power Curve of SSR

    • Solid State Relay, DC control AC, SSR-1025406080100 DA detail (6)zdq

      Solid State Relay Outline

    • Solid State Relay, DC control AC, SSR-1025406080100 DA detail (7)1jp

      State Relay Heatsink

    Leave Your Message